A Good Paper on Comparison of Approaches to Regulation of Different Countries

The paper titled "Ensuring Medical Device Effectiveness and Safety: A Cross-National Comparison of Approaches to Regulation" by Kramer et al. provided a systematic and in-depth comparisons of regulation of the US, EU, Japan, and China. The comparisons are based on six key features of device regulation:
  1. Regulatory Authority
  2. Pre-Market Evaluation
  3. Adverse Event Reporting
  4. Quality System Regulation
  5. Post-Approval Studies
  6. Post-Market Regulation Actions
Emerging strategies of post-approval surveillance were also discussed such as unique device identifier (UDI) system.

    New Final Guidance of 510(K) by the FDA

    On July 28, 2014, FDA issued the newest "Final Guidance of The 510(k) Program: Evaluating Substantial Equivalence in Premarket Notifications [510(k)]" after revised draft guidance issued in Dec 28, 2011. The final guidance gives more examples than the 2011 draft guidance to better illustrate the decision-making process during a 510(k) review. It also includes a sample 510(k) summary which is more much detailed than most 510(k) summary documents found on the FDA website. Special and Abbreviated 510(k) sections were removed. FDA intends to finalize these sections separately. Although FDA states that this guidance is "not intended to implement significant policy changes," the guidance clarifies and addresses many key issues in the 510(k) program.

    The US FDA requires that the manufacturers demonstrate safety and efficacy of the product, unless the devicecan be shown to be substantially equivalent (SE) to a predicate product that is legally marketed in the United States (via the 510(k)). For most new products, those without predicates, and certain high-risk products (typically Class III), a PMA is required. Certain Class I and exempted Class II medical devices are permitted to be marketed without the FDA’s prior authorization, although manufacturing(Quality System Regulations) and/or documentation controls may still apply. Some important points are summaried below:

    Predicate Device

    Predicate device is a the legally marketed device a legally marketed device, which is a device that (i) was legally marketed prior to May 28, 1976 (preamendments device) and for which a PMA is not required; or (ii) has been reclassified from Class III to Class II or I; or (iii) has been found SE through the 510(k) process. Although a manufacturer can identify multiple predicate devices, FDA recommends identifying a primary predicate in the submission.

    Wednesday, July 30, 2014

    Study Clinical Trials of Medical Device by FDA Bioresearch Monitoring (“BIMO”) program

    FDA Bioresearch Monitoring (“BIMO”) program are to protect the rights, safety, and welfare of human research subjects and to assure the quality, reliability, and integrity of data collected. It is a good source to learn good clinical practice, responsibilities of sponsors, clinical investigators, contract research organizations, monitors, institutional review boards in clinical trials of medical devices and preparing for FDA inspections. 

    Friday, July 18, 2014

    FDA Launches Online National Medical Device Curriculum

    FDA has launched a new learning tool for academic institutions and science and technology innovators called the National Medical Device Curriculum, to advance their understanding of FDA's medical device regulatory processes. The curriculum offers students FDA-endorsed knowledge about navigating the regulatory process, including how to design, test, and clinically evaluate devices; identify the root causes of adverse events and device malfunctions; and develop iterative device designs. The curriculum includes a series of four fictional case studies based on real-world medical device scenarios in a format similar to Harvard Business School Case Studies. 

    By understanding FDA's regulatory process, innovators can accelerate the delivery of innovative medical products to patients.

    Wednesday, June 25, 2014

    FDA guidance to nanotechnology products

    Nanotechnology is an emerging area which can create many new materials for medical devices, medicine, electronics and energy industries. On the other hand, more and more concerns about nanotechnology are raised about the toxicity and environmental impact of nanomaterials. 

    Today, FDA issues three final guidances and one draft guidance to support the responsible development of nanotechnology products (the link).

    In guidances, FDA has not established regulatory definitions of “nanotechnology,” “nanomaterial,” “nanoscale,” or other related terms. It aims to help industry when they should consider potential implications for regulatory status, safety, effectiveness, or public health impact that may arise with the application of nanotechnology in FDA-regulated products. FDA advises industry to consult with FDA early in the development process to facilitate a mutual understanding of the specific scientific and regulatory issues for their nanotechnology products.

    In "Guidance for Industry Considering Whether an FDA-Regulated Product Involves the Application of Nanotechnology", FDA identifies two Points to Consider that should be used to evaluate whether FDA-regulated products involve the application of nanotechnology.
    1. Whether a material or end product is engineered to have at least one external dimension, or an internal or surface structure, in the nanoscale range (approximately 1 nm to 100 nm);
    2. Whether a material or end product is engineered to exhibit properties or phenomena, including physical or chemical properties or biological effects, that are attributable to its dimension(s), even if these dimensions fall outside the nanoscale range, up to one micrometer (1,000 nm).

    Saturday, June 21, 2014

    Japan Visting

    This week we have a chance to visit the factory of a well-known Japan chemical & materials company. A ond-day visiting in Tokyo and some photos nearby the hotel:

    Suica

    Saturday, May 3, 2014

    Different Needs that Guide the Design and Development of Medical Devices

    The customers of medical devices are involved patient, doctor, nurse and purchasing agent who has different preference. The book Combination Products: Regulatory Challenges and Successful Product Development" (page 39) gives a summary of typical voices of customers for using combination products, which is a good reference for medical devices as well:
    • Patient: Needs to be safe, should be covered by insurance, result in minimum pain with no side effects, etc. 
    • Doctor: Needs to be easy to use/intuitive, have less morbidity/mortality and excellent and proven clinical benefits. Easy to place during procedure, excellent support from sales rep, overwhelming clinical superiority.
    • Nurse: Easy to use, store, unwrap, dispose, clean and sterilize; minimal nurse supervision of the patient. clear instructions with plenty of pictures, ergonomic and intuitive.
    • Purchasing agent: Cost-effective, reimbursable, excellent product-related service, clear codes that can easily be entered in system.

    Tuesday, April 1, 2014

    新修订的中国《医疗器械监督管理条例》Revised Version of “The Regulations for the Supervision and Administration of Medical Devices”

    昨天中国发布了修订的《医疗器械监督管理条例》。条例分为8章80条(相比2000年的条例为4章48条)。

    和2000年4月施行的条例(以下称旧条例)比较,一些个人感觉重要的修改总结如下: 

    1. 总则

    新条例第一条去掉了“为了加强对医疗器械的监督管理”。可能是为了突出“为了保证医疗器械的安全、有效”的医疗器械监督管理原则和目的。

    新条例将医疗器械的定义放在了附则部分。将旧条例中医疗器械所指的“单独或者组合使用于人体的仪器、设备、器具、材料或者其他物品”改为“直接或者间接用于人体的仪器、设备、器具、体外诊断试剂及校准物、材料以及其他类似或者相关的物品”。明确了间接用于人体的体外诊断(in vitro diagnostics)试剂和医疗器械等作为医疗器械的一部分。医疗器械使用目的中相应加入了“通过对来自人体的样本进行检查,为医疗或者诊断目的提供信息”。

    新条例增加了国务院和县级以上地方人民政府有关部门在各自的职责范围内负责与医疗器械有关的监督管理工作的内容。明确了有关部门如工商、卫生、质监、海关、公安等参与到医疗器械的生产、经营和使用的监督管理工作。

    Sunday, March 30, 2014

    Imagemagick

    Install Imagemagick, a powerful command line image tool, with Homebrew in my iMac.
    1. install XQuartz first, download file from http://xquartz.macosforge.org
    2. brew install imagemagick --with-x11
    3. convert logo: logo.gif; display logo.gif

    Friday, March 28, 2014

    Pass FDA 's Tests

    FDA websites, specially Center for Devices and Radiological Health (CDRH) is certain to the first study source for medical device industry and research. After study carefully of 21 CFR part medical device, cosmetics and drug, CDRH learn materials, I have passed serveral important tests.

    Saturday, March 1, 2014

    Factors to consider before a innovative idea to real market success in medical device.

    It is easy to find ideas that appear to have promising business potential, but ultimately very few have the potential for real market success. Many factors need considered before we determine if a idea will have real impact. Serveral considerations which may increase the chances of success in medical device development are listed:
    1. A new medical device must solve a real clinical problem or substantially lowers the cost of treatment and decreases mortality or serious morbidity relative to the standard of care.
    2. Understand how large the potential market (size and growth) for the new product is, and how ready the clinical users will be to adopt it.
    3. Learn intellectual property. Obtain protection of own patent and avoid infrigement of other's patents.
    4. Conduct clinical trials as early as possible if necessary.
    5. Plan the regulatory strategy early. The better you understand the regulatory framework, the greater your chance of success.
    6. Understand the reimbursement landscape.

    Online Medical Devices Registration: Licensale.com

    Medical device industry is highly regulated. Regulatory affairs of medical devices are complex and time-consuming procedures. Just find a unique, cloud-based, global regulatory system LICENSALE.COM from Arazy Group that simplifies international regulatory affairs.

    顾客满意-ISO 9001与ISO 13485的区别

    对比ISO 9001质量管理体系,ISO 13485医疗器械质量管理体系标准里没有“顾客满意”的要求,代之以“满足顾客要求”。标准中解释:“顾客满意”和“顾客感知度”在法规中作为要求来实施太过于主观。以“满足顾客要求”作为对质量管理体系绩效的测量,与ISO 13485反应当前监管法规和促进世界医疗器械监管法规协调的目标相一致。

    所谓“良药苦口”,医疗器械在保证安全、有效的前提下,有时不得不对产品使用的舒适性作出折中甚至舍弃一致降低了顾客满意度。同时,一味地追求顾客满意也会对医疗器械产品的研发、制造产生不利的影响。

    虽然现在的标准中未要求"顾客满意",但个人认为在保证医疗器械产品安全、有效的前提下,顾客的使用舒适性应在产品研发阶段给予充分考虑。同时,对顾客使用舒适性的反馈信息的深入分析结果是下一步产品开发和改进的重要的参考。通过考虑结和最新科技成果、仔细分析和评估风险/受益及应用人因工程学原理等,提供产品的使用舒适性,才能更好的开发出顾客满意度高的、具有强大市场竞争力的产品。

    Saturday, February 8, 2014

    Standards of Antimicrobial and Anti-biofilm Assay

    In the academic research, different labs and groups have their protocols for evaluating antimicrobial/antibiofilm properties of modified surfaces/materials and antimicrobial agents. In the industrial R&D, adopting international standards is more reliable and trusty. Below is the summary of main standards for antimicrobial/antibiofilm assay used in medical device industry:
    • Antimicrobial Effectiveness Tests in United States Pharmacopeia (USP) Chapter 51.
    • Zone of Inhibition, MIC, MBC:  refer to standards from the Clinical and Laboratory Standards Institute (CLSI).
    • ISO 22196, Measurement of Antibacterial Activity on Plastics and Other non-Porous Surfaces. (based on JIS Z 2801)
    • ISO 20743, Determination of Antibacterial Activity of Textile Products.
    • ASTM E2149, Standard Test Method for Determining the Antimicrobial Activity of Antimicrobial Agents Under Dynamic Contact Conditions.
    • ASTM E2180, Standard Test Method for Determining the Activity of Incorporated Antimicrobial Agent(s) in Polymeric or Hydrophobic Materials.
    • ASTM E2315, Standard Guide for Assessment of Antimicrobial Activity Using a Time-Kill Procedure.
    • ASTM E1054, Standard Test Methods for Evaluation of Inactivators of Antimicrobial Agents.
    • ASTM E1326 Standard Guide for Evaluating Nonconventional Microbiological Tests Used for Enumerating Bacteri.
    • JIS (Japan Industrial Standard) Z 2801, Antimicrobial products–Test for Antimicrobial Activity and Efficacy.
    • EN 1276, Chemical Disinfectants Bactericidal Activity Testing.
    • EN 1040, Basic Bactericidal Activity of Chemical Disinfectant. 
    • ASTM E2647, Standard Test Method for Quantification of Pseudomonas aeruginosa Biofilm Grown Using Drip Flow Biofilm Reactor with Low Shear and Continuous Flow.
    • ASTM E2196, Standard Test Method for Quantification of Pseudomonas aeruginosa Biofilm Grown with Medium Shear and Continuous Flow Using Rotating Disk Reactor.
    • ASTM E2562, Standard Test Method for Quantification of Pseudomonas aeruginosa Biofilm Grown with High Shear and Continuous Flow using CDC Biofilm Reactor.
    • Guidances and SOPs by the European Committee on Antimicrobial Susceptibility Testing (EUCAST).

    Saturday, December 7, 2013

    为什么苹果没有在日本出现?

    日本的电子、材料、机械制造工业水平很高。我相信苹果ipod、ipad、iphone在日本制造应该没有技术上的问题。但是问什么日本没有开发出这样的颠覆性创新产品。从最近和日本一家著名化学材料公司的合作中,了解了一些日本的产品研发情况,谈谈自己的一些看法。

    日本人性格上比较遵守规矩,做事情认真细致,强调团队精神。这是日本人从小就受到的教育。这样会限制了一些个性的发挥,导致缺少颠覆性创新能力。Peter Drucker在90年代指出日本公司喜欢创造性的模仿,满足于把产品作的更好而不是彻底的创新。

    日本公司的终身雇佣制、年功序列工资制度对员工的创新能力也有很大的影响。日本公司特别是大公司有点像以前的中国国企,员工基本上在一家公司工作到退休,按部就班地工作、升职。内部晋升是论资排辈,缺乏有效激励机制。跳槽对于日本公司员工不是个人发展的好选项。日本公司的年功序列制度也减少了跳槽的好处。员工跳槽到新公司,资历要从新算起,直接影响到奖金和以后的退休金,而且新公司对跳槽的员工也并不信任。这对稳定员工队伍、增强企业凝聚力、企业持续经营有好处。在日本公司里,拥有突出个人才能,不听上司话的年轻员工会被视为异端。这些因素都在一定程度上削弱了员工的创新能力。

    我认为日本公司技术至上的工程师文化,以技术为中心的创新(或者说是创造性的模仿), 而不是以客户为中心的产品开发是其缺少颠覆性创新产品的最重要原因。过于强调技术在产品开发中的重要性,一味准求制造超高质量的产品往往会弱化对市场和客户需求的真正了解。日本公司在技术上不可谓不强,尽管突破性的技术创新不如美国。日本公司将技术研发视为核心,以销售数量而不是市场和客户为导向,过于重视业绩,削弱了其创新能力。我认为:满足和引导客户(包括现有的和新的客户)的现有或未知需求, 为客户创造价值是产品研发和创新的最终目的。技术是实现这个目的的方法和手段之一,有时甚至不是关键的真正以市场驱动、客户为中心的产品开发是产品在市场成功的前提。客户为中心包括满足现有客户的新需求,甚至客户未知的需求和开发新的客户。开发新客户和满足现有客户的未知需求(有时要主动告诉消费者,他们需要什么) 往往是颠覆性创新的最重要目的。

    其他一些感想:
    日本公司推行的全面质量管理、改善法、精益生产对于提高产品质量、技术进步、减少浪费、增强企业运营效益具有非常积极的意义。但是正如Michael Porter在他的经典文章"What is strategy"中所说,运营效益并不是企业战略。只提高运营效益不能让企业取得持续性的竞争优势。提高运营效益类似于正确的做事,确定企业战略定位类似于做正确的事,往往做正确的事比正确的做事更关键、更重要。日本企业过度追求运营效益的改善,而忽略战略创新和定位,如果这种情况没有改善,日本企业80年代的辉煌很难再现。

    Sunday, December 1, 2013

    Videos from Nelson Labs

    Nice youtube videos from Nelson Labs on biocompatibility, sterilization, packaging validation tests is here. It gives in-depth understanding on related area after reading the International Standards.

    Saturday, November 9, 2013

    Quality Assurance vs Quality Control

    Quality assurance and quality control are two important aspects in quality management system. They often confuse R&D staffs especially scientists at the university who are not familar with the industry and manufacturing. Generally speaking, Quality Assurance (QA) is process oriented and focuses on defect prevention, while Quality Control (QC) is product oriented and focuses on defect identification. Good summary can be found: Difference of QA and QC. In my opinion, QA is to make sure do the thing right then naturally it lead to do the right thing. While QC focuses on investigate if we are doing the right thing.

    Thursday, October 10, 2013

    Smith&Nephew Global Wound Academy

    Smith&Nephew is a top company in wound management and surgery materials. They have a very good online study source of wound knowledge: Global Wounda Academy.


    Saturday, October 5, 2013

    Regulations of Medical Devices in Asia

    Handbook of Medical Device Regulatory Affairs in Asia is an excellent starting book to learn medcial device regulation in Asia. The handbook is the first to cover medical device regulatory affairs in Asia.

    Sunday, September 8, 2013

    Online Resource for Formulation, Raw Materials and Ingredients

    Good online formulation database including main chemical and cosmetic raw materials companies. So needn't search the companies one by one.
    Detailed chemical composition in household products.
    Chemicals used in Cosmetic in EC. can learn cosmetic ingredients according to their functions and cosmetic directive.